torna su
close Close

CEI membership discount

Dear customer,
our systems show that your name is connected to a company associated with CEI: you would therefore be entitled to thediscount reserved for our members for CEI products and services. To check the validity of the association and benefit from the discounts, it is necessary to enter the register number assigned to your company in the box below.

You can continue shopping even without entering the membership register number, but you will not have access to dedicated discounts.

CONTINUE WITHOUT DISCOUNTS

The membership register number has been correctly entered.
From now on, after logging into your MyNorma account, you can purchase our products at the price reserved for our members.

doneCONTINUE PURCHASING
Replaced help_outline

ISO 80601-2-79:2018

Medical electrical equipment - Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment
standard
IEC
IEC
Standard help_outline
Publication Date:  2018-07
Commitee:  IEC-TC62, IEC-SC62D
Language:  EN
Last Modification Date:  2024-12
Stability Date:  2024-08
ISO 80601-2-79:2018 This document applies to the basic safety and essential performance of ventilatory support equipment, as defined in 201.3.205, for ventilatory impairment, as defined in 201.3.202, hereafter also referred to as me equipment, in combination with its accessories:
— intended for use in the home healthcare environment;
— intended for use by a lay operator; and
— intended for use with patients who have ventilatory impairment, the most fragile of these patients, would not likely experience injury with the loss of this artificial ventilation; and
— not intended for patients who are dependent on artificial ventilation for their immediate life support.
EXAMPLE 1 Patients with mild to moderate chronic obstructive pulmonary disease (COPD).
NOTE 1 In the home healthcare environment, the supply mains is often not reliable.
NOTE 2 Such ventilatory support equipment can also be used in non-critical care applications of professional health care facilities.
This document is also applicable to those accessories intended by their manufacturer to be connected to the breathing system of ventilatory support equipment for ventilatory impairment, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory support equipment for ventilatory impairment.
EXAMPLE 2 Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system.
If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as relevant.
Hazards inherent in the intended physiological function of me equipment or me systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601‑1:2005+AMD1:2012, 7.2.13 and 8.4.1.
NOTE 3 Additional information can be found in IEC 60601‑1:2005+AMD1:2012, 4.2.
This document does not specify the requirements for:
— ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 80601‑2‑12;
— ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601‑2‑13[4];
— ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601‑2‑84 [5] [1], the future replacement for ISO 10651‑3[6];
— ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601‑2‑72;
— ventilatory support equipment or accessories intended for ventilatory insufficiency, which are given in ISO 80601‑2‑80[1];
— sleep apnoea therapy me equipment, which are given in ISO 80601‑2‑70[7];
— continuous positive airway pressure (CPAP) me equipment;
— high-frequency jet ventilators (HFJVs);
— high-frequency oscillatory ventilators (HFOVs)[8];
— oxygen therapy constant flow me equipment;
— cuirass or "iron-lung" ventilation equipment.
This document is a document in the IEC 60601 and IEC/ISO 80601 series of documents.
[1] Under preparation. Stage at the time of publication: ISO/DIS 80601-2-84:2017.

International Coding Standard (ICS)

11.040.10
Anaesthetic, respiratory and reanimation equipment
* Including medical gas installations

Annotation

PLEASE NOTE: links will be automatically recognized and made clickable when the annotation will be published

Standard Evolution

close

ICS

International Classification for Standards (ICS) is an international classification system for technical standards.

The ICS is a hierarchical classification organized on three levels.

Level 1 covers the main fields of activity in standardization, e.g. road vehicle engineering, agriculture, metallurgy.

Each field has a two-digit notation, e.g.

  43    Road Vehicle Engineering

The main fields are subdivided into groups (level 2). The notation of a group consists of the field notation and a three-digit group number, separated by a point, e.g.

  43.040    Road vehicle systems

Some groups are further divided into sub-groups (level 3). The notation of a sub-group consists of the group notation and a two-digit number, separated by a point, e.g.

  43.040.20 Lighting, signaling and warning devices

You can identify the ICS code of your interest by typing the code or a keywordword in the dropdown ICS field, and by selecting one of the filtered results.

Search also in the summary/description of the standard

By flagging this control, the search for keywords will not be limited to the Standard Number and Title fields, but will also be performed in the Abstract of the standard.

This way, you will get more results.

You should use this option when you can not find the desired result with the standard approach and it is necessary to extend the scope of the search: by increasing the number of results, you will increase the number of non-relevant elements, as well.