our systems show that your name is connected to a company associated with CEI: you would therefore be entitled to thediscount reserved for our members for CEI products and services. To check the validity of the association and benefit from the discounts, it is necessary to enter the register number assigned to your company in the box below.

You can continue shopping even without entering the membership register number, but you will not have access to dedicated discounts.

CONTINUE WITHOUT DISCOUNTS

The membership register number has been correctly entered.
From now on, after logging into your MyNorma account, you can purchase our products at the price reserved for our members.

doneCONTINUE PURCHASING
Replaced help_outline

D149:09

Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
standard
ASTM
ASTM
Standard
Test method help_outline
Designation:  D149:09
Publication Date:  2009-10
Commitee:  ASTM-D09.12
Language:  EN
BOS Volume:  10.01

1.1 This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. ,

1.2 Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem.

1.3 This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used (see 5.5).

1.4 It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium.

1.5 This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test.

1.6 This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method D3151).

1.7 This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). With the addition of instructions modifying Section 12, this test method is also suitable for use for proof testing.

1.8 This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7. Also see 6.4.1.




The dielectric strength of an electrical insulating material is a property of interest for any application where an electrical field will be present. In many cases the dielectric strength of a material will be the determining factor in the design of the apparatus in which it is to be used.

Tests made as specified herein are suitable for use to provide part of the information needed for determining suitability of a material for a given application; and also, for detecting changes or deviations from normal characteristics resulting from processing variables, aging conditions, or other manufacturing or environmental situations. This test method is useful for process control, acceptance or research testing.

Results obtained by this test method can seldom be used directly to determine the dielectric behavior of a material in an actual application. In most cases it is necessary that these results be evaluated by comparison with results obtained from other functional tests or from tests on other materials, or both, in order to estimate their significance for a particular material.

Three methods for voltage application are specified in Section 12: Method A, Short-Time Test; Method B, Step-by-Step Test; and Method C, Slow Rate-of-Rise Test. Method A is the most commonly-used test for quality-control tests. However, the longer-time tests, Methods B and C, which usually will give lower test results, will potentially give more meaningful results when different materials are being compared with each other. If a test set with motor-driven voltage control is available, the slow rate-of-rise test is simpler and preferable to the step-by-step test. The results obtained from Methods B and C are comparable to each other.

Documents specifying the use of this test method shall also specify:

Method of voltage application,

Voltage rate-of-rise, if slow rate-of-rise method is specified,

Specimen selection, preparation, and conditioning,

Surrounding medium and temperature during test,

Electrodes,

Wherever possible, the failure criterion of the current-sensing element, and

Any desired deviations from the recommended procedures as given.

If any of the requirements listed in 5.5 are missing from the specifying document, then the recommendations for the several variables shall be followed.

Unless the items listed in 5.5 are specified, tests made with such inadequate reference to this test method are not in conformance with this test method. If the items listed in 5.5 are not closely controlled during the test, it is possible that the precisions stated in 15.2 and 15.3 will not be obtained.

Variations in the failure criteria (current setting and response time) of the current sensing element significantly affect the test results.

Appendix X1. contains a more complete discussion of the significance of dielectric strength tests.

Relations

Replaces: D149:97a(2004)

Annotation

PLEASE NOTE: links will be automatically recognized and made clickable when the annotation will be published

Standard Evolution

close

ICS

International Classification for Standards (ICS) is an international classification system for technical standards.

The ICS is a hierarchical classification organized on three levels.

Level 1 covers the main fields of activity in standardization, e.g. road vehicle engineering, agriculture, metallurgy.

Each field has a two-digit notation, e.g.

  43    Road Vehicle Engineering

The main fields are subdivided into groups (level 2). The notation of a group consists of the field notation and a three-digit group number, separated by a point, e.g.

  43.040    Road vehicle systems

Some groups are further divided into sub-groups (level 3). The notation of a sub-group consists of the group notation and a two-digit number, separated by a point, e.g.

  43.040.20 Lighting, signaling and warning devices

You can identify the ICS code of your interest by typing the code or a keywordword in the dropdown ICS field, and by selecting one of the filtered results.

Search also in the summary/description of the standard

By flagging this control, the search for keywords will not be limited to the Standard Number and Title fields, but will also be performed in the Abstract of the standard.

This way, you will get more results.

You should use this option when you can not find the desired result with the standard approach and it is necessary to extend the scope of the search: by increasing the number of results, you will increase the number of non-relevant elements, as well.